Skip to main content
Technical

Semiconductor Fault Campaign: Why Silence Is Not Safe

Close-up of a silicon wafer showing rows of identical chip dies, with coloured light reflecting across the patterned surface

Thousands of simulated faults did nothing at all, and the metric improved because of it. What a fault campaign is for, why a fault must be activated before its silence means anything, and how a weak workload moves a hardware metric without any design change. New article, with a fictional 16-bit timestamp timer as the worked example.

A semiconductor fault campaign injects thousands of modelled faults into a simulation of a chip's design, then records which ones a safety mechanism detects. The results feed the diagnostic coverage and hardware metrics claimed for the part. The awkward result in any campaign is the fault that did nothing at all. Silence looks like good news, and a careless campaign books it as good news, whether or not the workload ever touched that fault.

What is a semiconductor fault campaign?

A semiconductor fault campaign is a large set of repeated simulations in which one fault is applied per run and the outcome is compared with a fault-free reference. It usually runs on a register-transfer or gate-level model, long before silicon exists. Each run answers two things: whether the fault disturbed anything that matters, and whether a safety mechanism reacted.

Campaigns exist because the safety analysis for a chip contains estimates. The coverage figures in a failure modes, effects and diagnostic analysis (FMEDA) often start as engineering judgement, and a campaign is one of the ways to check them against the actual design. The existing post on proving diagnostic coverage explains what injection can demonstrate about a mechanism. This article looks at the opposite end of the results, at the runs in which nothing visible happened.

Why can a silent fault not be counted as safe?

A silent fault cannot be counted as safe until the campaign has shown that it was activated. A stuck-at-0 fault holds a net at 0, so it can only change behaviour when the circuit tries to drive that net to 1. If the stimulus never asks for a 1, the faulty run and the reference run are identical, and the fault has not been tested in any meaningful sense.

A fictional timestamp timer shows how easily that happens. It is a 16-bit counter that sets an overflow flag at the end of its range, inside a network controller. The workload is a realistic transaction sequence lasting 10,000 clock cycles. Figure 1 traces the upper counter bits and the flag.

Timing diagram of a fictional 16-bit timer: bit 13 first rises at 8,192 cycles inside a 10,000 cycle workload, while bits 14 and 15 and the overflow flag first rise at 16,384, 32,768 and 65,536, beyond the end.
Figure 1. Lines that first rise past the workload's end are never activated by a stuck-at-0 fault. Fictional timer.

Bit 13 first rises at 8,192 cycles, so faults on it are activated. Bit 14 first rises at 16,384 and bit 15 at 32,768, and the overflow flag needs 65,536. The workload ends at about 15 % of the distance to overflow. A stuck-at-0 fault on bit 14, bit 15 or the flag therefore produces no difference whatsoever, and neither would anything downstream of them. The logic that handles overflow might be the very logic that a safety mechanism relies on, and the campaign has not exercised it.

How does a weak workload change the hardware metrics?

A weak workload changes the hardware metrics by moving untested faults into the safe column, which always flatters the result. Figure 2 follows a fictional block through the bookkeeping, using 10,000 faults and treating them as equally likely. Suppose the truth, which nobody can see directly, is 1,500 safe, 8,000 detected and 500 residual. A single-point style metric, one minus the residual share, is then 95.0 %.

Three stacked bars of 10,000 faults: the truth with 500 residual at 95.0 percent, what a 60 percent workload observes with 4,000 silent, and the result at 97.0 percent once those silent faults are booked as safe.
Figure 2. Booking silence as safe adds two points with no design change. All counts are illustrative.

Now run a workload that activates only 60 % of them. If activated faults behave like the rest, the campaign observes 900 safe, 4,800 detected and 300 residual, and 4,000 faults stay silent. Book those as safe, and the metric becomes 97.0 %. The design has not improved, and a target in that region, which an ASIL (Automotive Safety Integrity Level) on a specific project might impose, now appears to be met. Rarely exercised logic also tends to include error paths, so the silent faults may be worse than the average, and the real picture may be less friendly still.

The bias has a direction, which is what makes it dangerous. Random sampling error shrinks as the number of faults grows. This error does not. Simulating 100,000 faults with the same stimulus simply yields a more confident estimate of the wrong number, and a large fault count in a report offers no protection against it.

What should a reviewer look for in a campaign report?

A reviewer should look first for what happened to the faults that were never activated. An honest report keeps them visible as their own group, labelled as untested, until a better workload or a justified argument resolves them. A report showing only safe, detected and residual has made a decision without showing it. The second place to look is the workload itself, because any campaign result is a statement about one stimulus on one model. Asking how it was chosen and what it leaves unexercised is a fair question at any level of a chip supplier's documentation, and the broader context is covered in ISO 26262 for semiconductors.

The same principle applies when a campaign is reduced to save simulation time. Pruning and sampling are legitimate engineering, and they each carry assumptions that need to survive inspection. A campaign's value lies in how well it can defend its silent column.

The RTL and Semiconductor Fault Campaign Verification concept page adds fault models and abstraction levels, the campaign pipeline, full fault classification, cone-of-influence pruning, sampling with confidence, measuring workload adequacy, turning results into coverage and metrics, and a complete worked example with a review checklist.

Common questions about fault campaigns

Is a fault with no visible effect always a safe fault?

No. It may be masked for a good reason, or it may never have been activated. The classification depends on showing which of those happened, and on the safety mechanism's state.

Does simulating more faults fix a weak workload?

No. More samples reduce random error, while a weak workload causes a systematic one. Only better stimulus, or reporting the untested faults openly, addresses it.

Do fault campaigns replace the FMEDA?

No. A campaign provides evidence for selected claims in the analysis. Analytical reasoning and expert judgement can also support coverage, and many projects combine them.

Abbreviations & Key Definitions

  • Activation: The workload driving a fault site to the value the fault prevents.
  • ASIL: Automotive Safety Integrity Level, assigned for a specific project.
  • FMEDA: Failure modes, effects and diagnostic analysis.
  • RTL: Register-transfer level, a hardware design description.
  • Workload: The stimulus applied during each simulation run.

Read the full RTL and Semiconductor Fault Campaign Verification concept

From HARA to safety mechanisms: every concept with clear, practical explanations and real-world examples.

Start free

Free account: the complete Functional Safety Concept guide, 3 work-product templates, 5 practice exams a month and the Markov and RBD simulators. No credit card.

Keep learning

Guides on this topic.

The guide this article draws on, and where the topic leads next.

Browse all guides
PracticePractice examsExam-style questions with a written explanation for every answer. A free account includes 5 random practice exams a month.

Last updated: 24 November 2026

Share this article

Comments

Loading comments