Title: RTL and Semiconductor Fault Campaign Verification | ISO 26262 Academy
URL: https://iso26262.academy/features/concepts/semiconductor-fault-campaigns
Description: A chip FMEDA claims safe fractions and diagnostic coverage that nobody can reason out by hand for thousands of nets.

---
# RTL and Semiconductor Fault Campaign Verification

How a fault injection campaign on RTL or a gate-level netlist turns the safe fractions and coverage of a chip FMEDA into evidence: fault models, campaign anatomy, classification, cones, sampling, workload and reconciliation.

Concept guide · ISO 26262-11, Clauses 4 and 5 · ISO 26262-5 · 11 chapters

Included in [Expert](https://iso26262.academy/pricing#plan-advanced)

[Start free](https://iso26262.academy/register?plan=free&from=%2Fconcepts%2Fsemiconductor-fault-campaigns&utm_source=website&utm_medium=cta&utm_campaign=features_concepts) See the chapters

Free account: a preview of this guide, plus the full Functional Safety Concept guide, 3 templates and 5 exams a month.

11

Chapters

30

Figures

8

Campaign Stations

1

Worked Example

Inside the course

1. 01 **From the Vehicle to the Gate**
2. 02 **Fault Models: What Can Go Wrong in a Gate**
3. 03 **Why Chip FMEDA Numbers Need Evidence**
4. 04 **Anatomy of a Fault Injection Campaign**
5. 05 **Classifying Every Injected Fault**

## Quick answers

Why does a chip FMEDA need fault injection evidence?

For a block with thousands of nets nobody can reason through every failure mode by hand, and the architectural metrics react most strongly to coverage near the top of the scale, which is exactly where the demanding targets sit. A campaign measures the safe fraction and the diagnostic coverage on the implementation itself, so the FMEDA claims rest on evidence rather than on typical values.

Why can a weak workload make a design look safer than it is?

A fault the stimulus never activates leaves no trace, and a run without a trace tends to be booked as safe. A poor workload therefore does not just add noise, it biases the result toward a better metric. Simulating more faults with the same workload only makes the wrong number more confident; a better workload, or an explicit untested bucket that is not counted as safe, removes the bias.

Keep going, free

- [Demo exam · no account Test yourself with 7 exam-style questions](https://iso26262.academy/demo-exam)
- [Practice exams · 5 a month free How the practice exams work](https://iso26262.academy/features/exams)

## Benefits for your project

ISO 26262, Part 11

### Back every FMEDA claim with a run record

Safe fraction and diagnostic coverage are the numbers the block metrics are most sensitive to. The guide traces each claim in one FMEDA row to the campaign evidence behind it, so a reviewer can follow the chain instead of trusting a table value.

### Classify silence correctly

A run where nothing happened is where most classification mistakes are made. You get a decision tree from simulation record to fault class and conservative rules for the messy outcomes, so silent faults do not drift into the safe column by default.

### Size the sample and report the margin you achieved

The finite-population sample-size formula is worked step by step, with stratification, weighting and a guard band on the residual share. You learn why the margin you planned is not the margin you can claim.

### Resolve the mismatch instead of averaging it

The campaign and the FMEDA will disagree. A reconciliation guide covers the common mismatches, the first check for each, the honest resolutions, and the one move per symptom that makes the numbers agree by making the evidence worse.

## Related ISO 26262 guides

- [Hardware FPGA Safety Expert plan · 14 chapters](https://iso26262.academy/features/concepts/fpga-safety)
- [Software Software Architectural & Unit Design Pro plan · 11 chapters](https://iso26262.academy/features/concepts/software-architectural-unit-design)
- [Hardware Hardware Engineering in ISO 26262 Expert plan · 9 chapters](https://iso26262.academy/features/concepts/hardware-engineering-iso26262)

[All 109 guides](https://iso26262.academy/features/concepts#library)

## Learning outcomes

### Plan a campaign

Choose fault models and abstraction levels with a rationale, and place observation and diagnostic points for the claim being tested.

### Classify without bias

Turn run records into safe, detected, residual and latent faults, with conservative rules for silent and undecided outcomes.

### Prune and sample defensibly

Use cone analysis where it is proof, size a stratified sample, and report the margin actually achieved with a guard band.

### Judge a workload

Measure whether the stimulus gave every fault a chance to act before trusting a safe fraction.

### Close the loop with the FMEDA

Convert counts into DC, SPFM and LFM, resolve mismatches honestly, and know when a change forces a re-run.

## Chapters in this guide

1. 01
   **From the Vehicle to the Gate**
   RTL, gate-level netlists, fault sites and fault lists, and where fault campaigns sit in ISO 26262 and in the chip design flow.
   - Three views of a block
   - Fault sites and lists
   - Where campaigns run
2. 02
   **Fault Models: What Can Go Wrong in a Gate**
   Permanent, transient and timing fault models, the abstraction level each one needs, and when one model can stand in for another.
   - Fault model families
   - Matching the abstraction level
   - Stand-in arguments
3. 03
   **Why Chip FMEDA Numbers Need Evidence**
   What an integrated circuit FMEDA claims, where each number comes from, how sensitive the metrics are to those numbers, and who relies on the evidence.
   - What the FMEDA claims
   - Metric sensitivity
   - Who relies on it
4. 04
   **Anatomy of a Fault Injection Campaign**
   The eight stations from plan to report, observation points, diagnostic points and strobing, and a full plan for a lockstep comparator.
   - Eight stations
   - Strobing
   - A lockstep plan
5. 05
   **Classifying Every Injected Fault**
   The two questions asked of every run, why silent faults need extra checks before they count as safe, and conservative rules for undecided outcomes.
   - Observed and detected
   - Silent faults
   - Undecided outcomes
6. 06
   **Cone of Influence**
   Fan-in and fan-out cones, pruning the fault list into groups with different actions, and where structural reasoning stops being proof.
   - Fan-in and fan-out
   - Pruning with evidence
   - Limits of a cone
7. 07
   **How Many Faults: Sampling With Confidence**
   The statistical terms Part 11 names, the finite-population sample-size formula step by step, and why strata and achieved margins matter.
   - What a sample estimates
   - The formula
   - Stratify and report
8. 08
   **Workload Adequacy**
   Why a weak workload overstates safe faults, which measures reveal it, and how to choose the workload for each kind of claim.
   - The bias of a weak bench
   - Adequacy measures
   - Workload per claim
9. 09
   **From Campaign Results to DC, SPFM and LFM**
   Converting counts into failure rates, reconciling the mismatches between campaign and FMEDA, and running the work as a loop across design versions with a separate track for transients.
   - Counts to rates
   - Reconciliation
   - One loop, several passes
10. 10
    **Worked Example: an ECC-Protected Memory Controller**
    A complete campaign on a fictional block: fault list, collapsing, cone pruning, sampling, a workload that had to be rejected, classification, rates, metrics and the decisions taken when the results contradicted the FMEDA.
    - The fault list funnel
    - A rejected workload
    - Reconciling the metric
11. 11
    **Pitfalls and Review Checklist**
    Ten pitfalls mapped onto the campaign stations, the triggers that force a re-run, and a reviewer's checklist organised by artefact.
    - Ten pitfalls
    - Re-run triggers
    - Reviewer's checklist

Read all 11 chapters with Expert.

Start with a free account: a preview of this guide, the complete Functional Safety Concept guide and 5 practice exams a month, then upgrade when you need this guide.

[Expert](https://iso26262.academy/pricing#plan-advanced)

[Start free](https://iso26262.academy/register?plan=free&from=%2Fconcepts%2Fsemiconductor-fault-campaigns&utm_source=website&utm_medium=cta&utm_campaign=features_concepts) [Try the 7-question demo exam](https://iso26262.academy/demo-exam)

## Figures and diagrams in this guide

Diagrams & visuals

### RTL and Netlist Toggle

The same function as RTL text and as a gate-level netlist, with the fault sites each view exposes.

### Fault Model Gallery

Permanent, transient and timing fault models drawn as waveforms.

### Claim to Evidence Chain

One FMEDA row and the campaign evidence behind each of its numbers.

### Campaign Rail

The stations of a campaign from plan to report, with a token travelling through them.

### Outcome Matrix

Observed against detected: the four campaign outcomes and the fault classes they lead to.

### Cone Explorer

Click a netlist node to see its fan-out cone and whether it reaches an observation or diagnostic point.

### Workload Activation Slider

What a campaign reports as the workload gets weaker, while the design stays the same.

### Reconciliation Board

Common mismatches between campaign and FMEDA, the first check for each, and the honest resolutions.

## An ECC-Protected Memory Controller

Chapter 10

A complete campaign on a fictional memory controller, from the FMEDA claim to the final metric, including the point where the first workload had to be rejected and the design decisions that followed.

- The block, its FMEDA claim and the campaign plan
- The fault list reduced step by step through collapsing, cones and sampling
- First results and the workload review that rejected them
- Classified samples per stratum and the resulting failure rates
- The block metric from claim to final evidence

Inside the worked example

1. The block, its FMEDA claim and the campaign plan
2. Each point in the list, worked through step by step In the full guide

The full example is in the guide, part of the Expert plan.

## Who this guide is for

- Semiconductor safety engineers producing FMEDA and metric evidence for digital IP and SoCs
- Verification engineers planning or running fault simulation on RTL and gate-level netlists
- Safety managers at Tier 1s and OEMs who receive chip safety manuals and FMEDA reports
- Assessors and reviewers who need to judge whether a campaign report supports its coverage claims

## Questions about RTL and Semiconductor Fault Campaign Verification

Only one direction. If a fault site's cone reaches no observation or diagnostic point, there is no path and the fault cannot matter. If the cone does reach a point, it only says an effect is possible, and simulation or a careful functional argument has to show what actually happens. Constants, configuration registers, clock and reset nets and netlist changes each need extra care.

No. It is fictional, and so are its fault counts, rates and the agreed target it is measured against. Every step is shown with its arithmetic so you can redo the campaign logic for your own block.

## Consulting on RTL and Semiconductor Fault Campaign Verification

Have an engineer check your analysis, or help you build it. You get written findings on method, coverage and results.

From **$1,490** with a written quote before any charge

[See how we can help](https://iso26262.academy/features/consulting?service=analysis#sample)

## Start the RTL and Semiconductor Fault Campaign Verification guide

The full guide is part of the Expert plan. A free account opens a preview of it, the complete Functional Safety Concept guide, 3 work product templates, 1 guided process, the Markov and RBD simulators and 5 practice exams a month. No credit card required.

[Start free](https://iso26262.academy/register?plan=free&from=%2Fconcepts%2Fsemiconductor-fault-campaigns&utm_source=website&utm_medium=cta&utm_campaign=features_concepts) [View Pricing Plans](https://iso26262.academy/pricing)

Continue with

## More related ISO 26262 guides

[Browse all 109 guides](https://iso26262.academy/features/concepts#library)

- Software [Software Coding Guidelines](https://iso26262.academy/features/concepts/software-coding-guidelines) Learn how to select and enforce coding standards like MISRA C/C++, CERT C, and AUTOSAR C++ for safety compliance. Covers rule tailoring, static analysis, deviation management, and memory/timing/concurrency safety patterns. [Expert](https://iso26262.academy/pricing#plan-advanced) 16 chapters
- Hardware [Hardware Metrics](https://iso26262.academy/features/concepts/hardware-metrics) Learn how to calculate SPFM, LFM, and PMHF with correct failure rate data and diagnostic coverage values. Covers ASIL-dependent targets, data sources (IEC 61709, FIDES), common calculation pitfalls, and compliance strategies. [Pro](https://iso26262.academy/pricing#plan-basic) [Expert](https://iso26262.academy/pricing#plan-advanced) 16 chapters
- Hardware [FMEDA: Quantitative Hardware Safety Analysis](https://iso26262.academy/features/concepts/fmeda) Learn how Failure Modes, Effects and Diagnostic Analysis turns component failure rates in FIT, failure-mode distributions, and diagnostic coverage into the SPFM, LFM, and PMHF metrics that ISO 26262-5 requires for safety-related hardware. [Expert](https://iso26262.academy/pricing#plan-advanced) 10 chapters
